NEW: temperature sensor by TRANBERG

Technical Data

Ex-protection II 2G Ex mb IIC T6 Gb

Area of use Zone 1, Zone 2 and safe area

Material Brass, Chromium-plated brass or Acid resistant stainless steel

Max supply voltage 250V AC

Ambient temp. range -50°C to +50°C

Max surface temp. +50°C

Max ambient temp before damage of bimetal thermostat +177°C T-rating T6.

Applications

The thermostat must be protected with max. 16A circuit breaker (fuse) on power lead.

When used in Ex Classified Zones, ATEX Certified circuit breaker must be used.

Electrical connection to the heater must be executed via a circuit breaker, max. 16A and terminals mounted inside an enclosure..( See fig. 1 on the datasheet)

Details

  • TRANBERG